  • Module throughput uses 13.5 kW per station, the middle of the 11–16 kW measured on the R75108 bench, with 12 channels and 5 min per module swap (offer basis). The inferred ceiling is near 37 kW. Decided 10 Nov: modules stay on the public page.
  • Optimised recipes act on packs only (103 → 72 min, MODELLED on the Sept analysis). Modules stay unchanged because no module figure exists.
  • No prices on the page (decided 10 Nov). Stations are counted, not priced.
  • Defaults: 3,000 t a year, 80 % packs by mass, 75 kWh / 450 kg pack, 70 % charge on arrival (so 52.5 kWh to remove, close to the measured 52 kWh average), 2 shifts, 220 days.
Sizing simulator · estimates

How many stations for your line

Enter your tonnage and battery mix. The simulator sizes RE-GEN 90 discharge stations on times measured at a working pre-treatment site, and shows what optimised recipes change.

SIMULATIONEstimates only. Real results on end-of-life batteries depend on battery condition and ambient conditions.

Your line

Whole packs go on the pack channel. Modules go on the module channels. A station runs one mode at a time.
kWh
kg
kWh
kg
Module channels take modules up to 110 V. Higher-voltage modules go on the pack channel.
Standard recipe
RE-GEN 90 stations
Per pack on station
Station load
Measured timesMEASURED
Optimised recipes
RE-GEN 90 stations
Per pack on station
Station load
One pass, no waitingMODELLED
Packs a day
Modules a day
Energy recovered a year

Want this sized on your own battery list? Send us your figures. We reply with a scoping call and a budget estimate.

Send my figures
Where the figures come from
FigureValueSource
Average power while current flows, EV pack44 kWMEASURED · 16 full EV packs on a customer's line, Oct 2026
Waiting on the station per pack, standard recipe32 minMEASURED · same packs (103 min on the station, 71 with current flowing)
Waiting with optimised recipes≈ 1 minMODELLED · one pass without waiting between steps, −31 min per battery (analysis of 206 batteries, Sep 2026). To validate in a pilot.
Module station power13.5 kWMEASURED · middle of 11–16 kW on our test bench, 12 module channels
Module swap per channel5 minESTIMATE · our design basis
Station availability85 %ESTIMATE · our design basis, covers breaks and maintenance
Shift length8 hESTIMATE
Energy recoveredcapacity × chargeESTIMATE · energy taken out of the batteries, before conversion losses

Every station discharges to 0 V and holds against rebound. The operator does the final short-circuit. Station counts include no spare: we size headroom with you on your own battery list. Nothing you enter here is stored or sent, until you press the button and send the email yourself.